Review





Similar Products

90
Boston Scientific Corporation 0.035-inch jagwire
0.035 Inch Jagwire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/0.035-inch jagwire/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
0.035-inch jagwire - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation hydra jagwire 0.035
Table 1 Thermal changes produced by commercially available guidewires during electrical conductance via surgical generator in our experiment.
Hydra Jagwire 0.035, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hydra jagwire 0.035/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
hydra jagwire 0.035 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Microvasive Inc jagwire 0.035
Table 1 Thermal changes produced by commercially available guidewires during electrical conductance via surgical generator in our experiment.
Jagwire 0.035, supplied by Microvasive Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/jagwire 0.035/product/Microvasive Inc
Average 90 stars, based on 1 article reviews
jagwire 0.035 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewire for non-vascular use hydra jagwire, 0.035-inch
Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a <t>guidewire</t> is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).
Guidewire For Non Vascular Use Hydra Jagwire, 0.035 Inch, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/guidewire for non-vascular use hydra jagwire, 0.035-inch/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
guidewire for non-vascular use hydra jagwire, 0.035-inch - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewire jagwire 0.035
Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a <t>guidewire</t> is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).
Guidewire Jagwire 0.035, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/guidewire jagwire 0.035/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
guidewire jagwire 0.035 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation 0.035-inch stiff guidewire jagwire
The <t>fluoroscopic</t> view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).
0.035 Inch Stiff Guidewire Jagwire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/0.035-inch stiff guidewire jagwire/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
0.035-inch stiff guidewire jagwire - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewire jagwire 0.035-diameter
The <t>fluoroscopic</t> view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).
Guidewire Jagwire 0.035 Diameter, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/guidewire jagwire 0.035-diameter/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
guidewire jagwire 0.035-diameter - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation 0.035-inch guidewire jagwire
The <t>fluoroscopic</t> view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).
0.035 Inch Guidewire Jagwire, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/0.035-inch guidewire jagwire/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
0.035-inch guidewire jagwire - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation guidewires boston scientific jagwire 0.035-mm
The <t>fluoroscopic</t> view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).
Guidewires Boston Scientific Jagwire 0.035 Mm, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/guidewires boston scientific jagwire 0.035-mm/product/Boston Scientific Corporation
Average 90 stars, based on 1 article reviews
guidewires boston scientific jagwire 0.035-mm - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Table 1 Thermal changes produced by commercially available guidewires during electrical conductance via surgical generator in our experiment.

Journal: Endoscopy International Open

Article Title: Thermal changes in guidewires used during endoscopic retrograde cholangiopancreatography during electrical conductance: Ex-vivo safety experiment

doi: 10.1055/a-2536-7997

Figure Lengend Snippet: Table 1 Thermal changes produced by commercially available guidewires during electrical conductance via surgical generator in our experiment.

Article Snippet: We tested heat generation of 11 wires commonly used in ERCP: Glidewire 0.018” (Terumo Interventional Systems, Somerset, New Jersey, United States), Novagold 0.018” (Boston Scientific, Marlborough, Massachusetts, United States), Road Runner 0.018” (Cook Medical, Bloomington, Indiana, United States), Tracer Metro 0.021” (Cook Medical, Bloomington, Indiana, United States), Glidewire 0.025” (Terumo Interventional Systems, Somerset, New Jersey, United States), Visiglide 0.025” (Olympus, Center Valley, Pennsylvania, United States), Revowave 0.025” (Olympus, Center Valley, Pennsylvania, United States), Jagwire Revolution 0.025” (Boston Scientific, Marlborough, Massachusetts, United States), Glidewire 0.035” (Terumo Interventional Systems, Somerset, New Jersey, United States), Jagwire 0.035” (Boston Scientific, Marlborough, Massachusetts, United States), and Hydra Jagwire 0.035” (Boston Scientific, Marlborough, Massachusetts, United States) ( ).

Techniques: Produced

Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a guidewire is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).

Journal: DEN Open

Article Title: Recurrence rate of cholecystitis after initial gallbladder stenting versus secondary gallbladder stenting: A propensity score matching study

doi: 10.1002/deo2.70047

Figure Lengend Snippet: Endoscopic gallbladder stenting method. A catheter is inserted into the bile duct, and a guidewire is advanced into the gallbladder. The catheter is followed by the guidewire, and a stent is placed in the gallbladder after cholecystography is performed (cited from the Canadian Journal of Gastroenterology and Hepatology [15]).

Article Snippet: Angiographic guidewire (Radifocus, 0.032‐inch [Terumo Corp.], disposable guidewire [VisiGlide 2, 0.025‐inch {Olympus}], endoscopic guidewire [VENTY, 0.025‐inch {Boston Scientific Corp.}], and guidewire for non‐vascular use [Hydra Jagwire, 0.035‐inch {Boston Scientific}]).

Techniques:

Fluoroscopic images. (a) Fluoroscopic image of gallbladder intubation. The guidewire is looped in the gallbladder. (b) Fluoroscopic image of a stent placed in the gallbladder.

Journal: DEN Open

Article Title: Recurrence rate of cholecystitis after initial gallbladder stenting versus secondary gallbladder stenting: A propensity score matching study

doi: 10.1002/deo2.70047

Figure Lengend Snippet: Fluoroscopic images. (a) Fluoroscopic image of gallbladder intubation. The guidewire is looped in the gallbladder. (b) Fluoroscopic image of a stent placed in the gallbladder.

Article Snippet: Angiographic guidewire (Radifocus, 0.032‐inch [Terumo Corp.], disposable guidewire [VisiGlide 2, 0.025‐inch {Olympus}], endoscopic guidewire [VENTY, 0.025‐inch {Boston Scientific Corp.}], and guidewire for non‐vascular use [Hydra Jagwire, 0.035‐inch {Boston Scientific}]).

Techniques:

The fluoroscopic view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).

Journal: VideoGIE

Article Title: Disrupted pancreatic duct with pancreaticocutaneous fistula after percutaneous pseudocyst drain: conversion to internal drainage with transgastric stents

doi: 10.1016/j.vgie.2024.05.011

Figure Lengend Snippet: The fluoroscopic view shows the EUS-guided puncture of the pancreatic duct in the mid-body where contrast injection illustrates a complete pancreatic duct disruption ( solid arrow ).

Article Snippet: A long 0.035-inch stiff guidewire (Jagwire; Boston Scientific, Marlborough, Mass, USA) was inserted through the needle into the fistula cavity under fluoroscopic guidance ( ).

Techniques: Injection, Disruption

Fluoroscopic view shows the 0.035-inch stiff guidewire (Jagwire) that was captured by IR team using an endovascular snare to pull out via the abdominal wall (not visible in this image).

Journal: VideoGIE

Article Title: Disrupted pancreatic duct with pancreaticocutaneous fistula after percutaneous pseudocyst drain: conversion to internal drainage with transgastric stents

doi: 10.1016/j.vgie.2024.05.011

Figure Lengend Snippet: Fluoroscopic view shows the 0.035-inch stiff guidewire (Jagwire) that was captured by IR team using an endovascular snare to pull out via the abdominal wall (not visible in this image).

Article Snippet: A long 0.035-inch stiff guidewire (Jagwire; Boston Scientific, Marlborough, Mass, USA) was inserted through the needle into the fistula cavity under fluoroscopic guidance ( ).

Techniques: